Home
> Web Datasheet
|
||||
| ALL RATINGS ARE @ Tc = 25 °C UNLESS OTHERWISE SPECIFIED. | ||||
Disclaimer
|
| |
| MAXIMUM RATINGS / Conditions | SYMBOL | MAX | UNITS |
| PEAK INVERSE VOLTAGE | PIV | 200 | Volts |
| MAXIMUM DC OUTPUT CURRENT @ Tc=55 °C) | lo | 1 | Amps |
| MAXIMUM DC OUTPUT CURRENT @ Tc=100 °C) | lo | 2 | Amps |
| MAXIMUM NON-REPETITIVE FORWARD SURGE CURRENT (t= 8.3ms, Sine) |
lFSM | 30 | Amps |
| MAXIMUM THERMAL RESISTANCE | RØJC | 38 | °C/W |
| OPERATING TEMPERATURE | TJ(MAX) | -65 to +175 | °C |
| ELECTRICAL CHARACTERISTICS / Conditions | SYMBOL | MAX | UNITS |
| MAXIMUM FORWARD VOLTAGE DROP, Pulsed (lf
= 1 Amps) TA = 25 °C |
Vf | 1.1 | Volts |
| MAXIMUM REVERSE CURRENT TA = 25 °C TA = 150 °C |
Ir | 1 3 |
uA uA |
| REVERSE RECOVERY TIME |
trr | 5000 | ns |
MECHANICAL DIMENSIONS: In Inches / mm
*This drawing is for reference only. |