High Power Protection (MIL-STD- 1275)

Part Number : SCP-5282-36

High Pulse Power Transorb - Clamp below 39.00V Vdc


Key Features :
  • Clamping below 39.00V Vdc for 100V
  • High Pulse Power Capability
  • Uni

Protection Level :
  • 100V Surge withstanding for 100 msec with 0.5-ohm source impedance
  • 100% tested for 100/50ms

Electrical Characteristics : (All parameters are at Tc = 25°C unless otherwise specified)
RATING CONDITIONS SYMBOL MIN TYP MAX UNIT
Peak Pulse Power Dissipation   Ppk -   10kW KW
Reverse Stand-Off Voltage VWM -   34V Volts
Reverse Leakage @VWM Io -   12mA mA
Breakdown Voltage   VBR 36.45V     Volts
Clamping Voltage @IPP VC     39.00V Volts
Peak Pulse Current   IPP     100A Amps



Request Quote